Sunday, October 3, 2021

NRC Proposes $45,000 Fine to Terracon Consultants, Inc.

Nuclear Regulatory Commission - News Release
No: IV-21-014 October 1, 2021
Contact: Victor Dricks, 817-200-1128


NRC Proposes $45,000 Fine to Terracon Consultants, Inc.

The Nuclear Regulatory Commission is proposing a $45,000 fine to Terracon Consultants Inc. of Olathe, Kansas, for five violations of NRC requirements involving the loss of control of a portable nuclear gauge.

The violations involve:

  • Failure by Terracon to control and maintain constant surveillance of licensed material.

  • Failure to use an approved container for the transport of licensed material.

  • Failure to lock or place the gauge inside a container to prevent unauthorized or accidental removal.

  • Failure to properly block and brace the canister from movement during transportation.

  • Failure to provide required notification to the NRC immediately following discovery of its loss, as described in an April 1 inspection report.
NRC staff met virtually with company representatives on May 20, 2021, during a pre- decisional enforcement conference to discuss the violations, which stem from a Nov. 25, 2019, incident in which a worker placed an unsecured portable nuclear gauge in the bed of a truck and drove away from a temporary job site in Killingly, Connecticut, and lost the gauge.

The gauge was subsequently recovered, but the technician did not provide complete and accurate information regarding the circumstances of the event during interviews with company officials.

The company has 60 days to dispute the fine or request involvement of a neutral third-party mediator to resolve the issues.

NRC Proposes $150,000 Civil Penalty to Entergy Operations, Inc.

Nuclear Regulatory Commission - News Release
No: IV-21-013 October 1, 2021
Contact: Victor Dricks, 817-200-1128

NRC Proposes $150,000 Civil Penalty to Entergy Operations, Inc.

The Nuclear Regulatory Commission is proposing a $150,000 fine to Entergy Operations Inc. for three willful violations of agency requirements at the River Bend nuclear power plant. Entergy operates the plant in St. Francisville, Louisiana.

The violations involved:

  • On Aug. 13, 2018, a proctor made an unauthorized copy of an exam after thinking he had lost pages of the exam taken by the examinee. He then falsified answers on behalf of the examinee and submitted it.

  • On Sept. 1, 2019, a non-licensed operator assigned to the plant’s control building failed to properly complete a tour of all areas as required.

  • On March 31, 2020, a senior reactor operator provided a key to a maintenance supervisor who was not authorized to receive it and the supervisor accessed a room containing
cybersecurity-related equipment.

NRC staff met with company representatives virtually on Aug. 16, 2021, during a pre-decisional enforcement conference to discuss the violations as described in a July 1, 2021, inspection report. The company has 60 days to dispute the fine or request involvement of a neutral third-party mediator to resolve the issues.

NRC to Hold Virtual Regulatory Performance Meeting to Discuss Supplemental Inspection Results for Grand Gulf Nuclear Power Plant

Nuclear Regulatory Commission - News Release
No: IV-21-012 September 30, 2021
Contact: Victor Dricks, 817-200-1128


NRC to Hold Virtual Regulatory Performance Meeting to Discuss Supplemental Inspection Results for Grand Gulf Nuclear Power Plant

Nuclear Regulatory Commission staff will discuss the results of a recent onsite supplemental inspection of the Grand Gulf nuclear power plant during a virtual meeting to be held Oct. 4.

The session will run from 5-7 p.m., Central time. Following registration, a confirmation email will be sent with details on how to join the video webinar. To listen to the audio presentation, participants must call 888-323-9703 and enter passcode 1786567#. The meeting will be recorded and later made available on the NRC website.

NRC staff responsible for plant inspection and oversight will participate in the discussion, including the Region IV Regional Administrator and the supplemental inspection team leader. NRC staff will discuss the results of a comprehensive inspection conducted between Aug. 23 and Sept. 17 in response to the station’s degraded performance in 2020. Officials from Entergy Operations, Inc., which operates the plant, will discuss their performance improvement plan. Members of the public will have an opportunity to ask questions of NRC staff following the business portion of the meeting.

Grand Gulf, located in Port Gibson, Mississippi, continues to operate safely. Because of the number of unplanned plant shutdowns in 2020, the plant is receiving increased oversight and inspection focus.

The annual assessment letter for Grand Gulf is available on the NRC website. Current performance information for the plant is also available and is updated on a quarterly basis.

Tuesday, September 28, 2021

Susquehanna Steam Electric Station, Units 1 and 2 - Security Baseline Inspection Report 05000387/2021402 and 05000388/2021402

Susquehanna Steam Electric Station, Units 1 and 2 - Security Baseline Inspection Report 05000387/2021402 and 05000388/2021402

ADAMS Accession No.  ML21266A212

Peach Bottom Atomic Power Station, Units 2 and 3 - Biennial Problem Identification and Resolution Inspection Report 05000277/2021012 and 05000278/2021012

Peach Bottom Atomic Power Station, Units 2 and 3 - Biennial Problem Identification and Resolution Inspection Report 05000277/2021012 and 05000278/2021012

ADAMS Accession No.  ML21265A334

Wednesday, September 15, 2021

WASTE MANAGEMENT Release of La Crosse and Zion sites for unrestricted use delayed until 2022 Mon, Sep 13, 2021, 8:00AMRadwaste Solutions

WASTE MANAGEMENT

Release of La Crosse and Zion sites for unrestricted use delayed until 2022
Mon, Sep 13, 2021, 8:00PMRadwaste Solutions

The La Crosse site in 2019 with major decommissioning completed. The coal-fired Genoa plant is in the background. (Photo: EnergySolutions)

The Nuclear Regulatory Commission has extended its orders transferring the licenses for the La Crosse and Zion nuclear power plants from EnergySolutions back to the plant owners until late 2022. This is the third time the NRC has extended the effectiveness of the license transfer orders for the decommissioned plants since approving them in 2019.

EnergySolutions, which took over the licenses for the Zion plant in Illinois and the La Crosse boiling water reactor in Wisconsin for expedited decommissioning, requested the 12-month extensions as it works to respond to requests from the NRC for additional information regarding the final status survey reports (FSSRs) for the two sites. The NRC issued the extension orders for La Crosse and Zion on August 30 and published notice in the September 7 Federal Register.

LaCrosse: EnergySolutions subsidiary LaCrosseSolutions acquired the La Crosse site license from the Dairyland Power Cooperative in 2016. On November 12, 2019, the company announced that it had completed the physical work of decommissioning the plant, which was shut down in 1987 and had already been partially decommissioned.

By a September 2019 order, the NRC consented to the transfer of the La Crosse license back to Dairyland Power. Unless good cause could be shown for extending it, the NRC order was to become null and void if the license transfer was not completed within one year.

LaCrosseSolutions twice applied to the NRC to extend the order’s September 2020 expiration date for an additional six months, first in June 2020 and again in February 2021. The NRC approved both extensions.

In August this year, the company again requested that the order be extended, this time for an additional 12 months, to September 2022. In requesting the extension, LaCrosseSolutions noted that NRC staff is continuing to review the site’s FSSRs. “Based on the current status of the NRC review, it is anticipated that additional time will be needed to address any questions or potential issues identified by the NRC during review of the responses to the request for additional information and the revised FSSRs,” the company said.

Zion: Similarly, EnergySolutions subsidiary ZionSolutions requested in August that the transfer of Zion’s license back to Exelon Generation be extended by 12 months, after previously being granted two six-month extensions, one in October 2020 and the other in May 2021. The NRC first approved the transfer order in November 2019, following ZionSolutions’ completion of the majority of decommissioning work at Zion.

ZionSolutions, in requesting the extension, likewise noted that more time was needed to respond to NRC staff requests for information regarding the site’s FSSRs. “The extension provides the NRC staff with additional time to assess the responses provided by ZionSolutions and make a final determination regarding the release of land for unrestricted use,” the company said.

On August 19, the NRC sent ZionSolutions a 38-page letter with 11 requests for additional information regarding radiological conditions at the Zion site.

TMI - OFFSITE NOTIFICATION DUE TO CONTRACTOR FATALITY

Power Reactor
Event Number: 55455
Facility: Three Mile Island
Region: 1      State: PA
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP
NRC Notified By: Brian Miscavage
HQ OPS Officer: Thomas Kendzia Notification Date: 09/10/2021
Notification Time: 14:45 [ET]
Event Date: 09/10/2021
Event Time: 10:55 [EDT]
Last Update Date: 09/10/2021 Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
72.75(b)(2) - Press Release/Offsite Notification Person (Organization):
DENTEL, GLENN (R1)
MILLER, CHRIS (NRR EO)
RIVERA-CAPELLA, GRETCHEN (NMSS DAY)
GOTT, WILLIAM (IR)
NMSS_EVENTS_NOTIFICATION, (EMAIL)


Power Reactor Unit Info
UnitSCRAM CodeRX CritInitial PWRInitial RX ModeCurrent PWRCurrent RX Mode
1NN0Defueled0Power Operation

Event Text
OFFSITE NOTIFICATION DUE TO CONTRACTOR FATALITY

"This is a four-hour notification, non-emergency for a notification of another government agency. This event is being reported under 10 CFR 50.72(b)(2)(xi) and 10 CFR 72.75(b)(2).

"At 1055 EDT on 9/10/21, an employee of a site contractor that was performing work under a contract and in possession of the immediate area where the work was being performed, was involved in a material handling accident in the owner controlled area at Three Mile Island. Londonderry Township EMS and Fire responded to render assistance to the individual. Upon arrival to the site, medical personnel declared the individual deceased.

"The fatality was work related and the individual was outside of the Radiological Controlled Area."