PART 21 - DEFECT IN LOCA ANALYSIS FOR B&W PLANTS
The following information was summarized from the report obtained from the vendor via facsimile:
"The
defect is related to the thermal conductivity model in the codes TACO3
and GDTACO which are used in the AREVA LOCA model for B&W plants.
The thermal conductivity model does not adequately represent the change
in conductivity with burnup for the fuel. The correction of the thermal
conductivity model results in the peak cladding temperature limit in 10
CFR 50.46 (2200 degrees F) being exceeded.
"The
defect exists for the following plants: Oconee Nuclear Station Unit 1,
Oconee Nuclear Station Unit 2, Oconee Nuclear Station Unit 3, Arkansas
Nuclear One Unit 1, Three Mile Island Unit 1, and Davis-Besse Unit 1"
If there are any technical questions or concerns, please contact:
Gayle Elliott AREVA, lnc., 3315 Old Forest Road Lynchburg, VA 24501 Ph. # 434-841-0306.
|
No comments:
Post a Comment